Common setup problem : No Frequency Warning
Jump to navigation
Jump to search
If you use NOFRQS in the PATHDATA file then, make sure to use NOFRQS in the ODATA.CONNECT file.
For example if the PATHDATA file looks like following:
SLURM CYCLES 100 ADDPATH path.info.first TEMPERATURE 0.592 PLANCK 9.536D-14 EXEC /home/ab2480/svn/OPTIM/builds/AMBER/A12OPTIM NATOMS 68 COPYFILES perm.allow min.in coords.prmtop coords.inpcrd COPYOPTIM DIRECTION BA CONNECTREGION 1 2 200 CONNECTIONS 1 ITOL 10.0D0 NOFRQS GEOMDIFFTOL 0.3D0 EDIFFTOL 1.0D-4 PERMDIST AMBER12
ODATA.CONNECT file should be :
REOPTIMISEENDPOINTS UPDATES 20 4 20 10 4 NEWCONNECT 20 3 10.0 40.0 50 2.0 0.001 NEWNEB 40 400 0.1 NEBK 10.0 NOCISTRANS DIJKSTRA EXP DUMPALLPATHS CHECKCHIRALITY EDIFFTOL 1.0D-4 MAXERISE 1.0D-4 1.0D-2 GEOMDIFFTOL 0.1D0 BFGSTS 1000 20 200 0.01 100 BFGSMIN 1.0D-6 NOHESS NOFRQS PERMDIST MAXSTEP 0.2 TRAD 0.5 MAXMAX 1.0 BFGSCONV 1.0D-6 PUSHOPT 0.2 0.001 100 STEPS 1000 BFGSSTEPS 60000 MAXBFGS 0.2 AMBER12 start