Common setup problem : No Frequency Warning

From Docswiki
Revision as of 13:56, 18 July 2019 by Ab2480 (talk | contribs)
Jump to navigation Jump to search

If you use NOFRQS in the PATHDATA file then, make sure to use NOFRQS in the ODATA.CONNECT file.

For example if the PATHDATA file looks like following:

SLURM
CYCLES 100
ADDPATH path.info.first
TEMPERATURE 0.592
PLANCK  9.536D-14
EXEC /home/ab2480/svn/OPTIM/builds/AMBER/A12OPTIM
NATOMS 68
COPYFILES perm.allow min.in coords.prmtop coords.inpcrd
COPYOPTIM
DIRECTION BA
CONNECTREGION 1 2 200
CONNECTIONS 1
ITOL 10.0D0
NOFRQS
GEOMDIFFTOL 0.3D0
EDIFFTOL 1.0D-4
PERMDIST
AMBER12

ODATA.CONNECT file should be :

REOPTIMISEENDPOINTS
UPDATES 20 4 20 10 4
NEWCONNECT 20 3 10.0 40.0 50 2.0 0.001
NEWNEB 40 400 0.1
NEBK 10.0
NOCISTRANS
DIJKSTRA EXP
DUMPALLPATHS
CHECKCHIRALITY
EDIFFTOL  1.0D-4
MAXERISE 1.0D-4 1.0D-2
GEOMDIFFTOL  0.1D0
BFGSTS 1000 20 200 0.01 100
BFGSMIN 1.0D-6
NOHESS
NOFRQS
PERMDIST
MAXSTEP  0.2
TRAD     0.5
MAXMAX   1.0
BFGSCONV 1.0D-6
PUSHOPT 0.2 0.001 100
STEPS 1000
BFGSSTEPS 60000
MAXBFGS 0.2
AMBER12 start