Sometimes in OPTIM high energy transition states will be encountered. There are several strategies for understand why these are occurring.

1. OPTIM and PATHSAMPLE may be able to fine lower energy connections if the calculations are allowed to continue. This can very inefficient. One way of preventing high energy transition states from occurring is to explicitly prevent transition states of a certain energy or above from being allowed. This is done by using the keyword MAXTSENERGY in both PATHSAMPLE and OPTIM.

2. If letting the calculation resolve the problem or MAXTSENERGY does not work looking at the interpolation is necessary. In order to do so, new OPTIM keywords, DEBUG, DUMPNEBEOS, and DUMPNEBXYZ need to be added to print the NEB interpolated energy and coordinates in the files neb.xyz.31267.<n>, and neb.EofS.<n>.31267.