CamCASP/Programming/3

From CUC3
Revision as of 16:27, 26 February 2009 by import>Am592 (→‎Outline)
Jump to navigation Jump to search

CamCASP => Programming => Robust integrals

Outline

At present, we calculate our 4-index 2-electron integrals in the following way (chemical notation):

<math>

 (pq|rs) \approx (\tilde{pq}|\tilde{rs}) = D^A_{pq,k} (k|l) D^B_{rs,l}

</math>

where we have assumed <math>p,q ~ (r,s)</math> belong to molecule A (B). This method is not good enough as the integrals have errors that are first order in the error in the density. Here's why:

We have:

<math>

 |pq) = |\tilde{pq}) + \delta_{pq} 

</math>

which implicitly defines the error <math>\delta_{pq}</math>. Using this, our approximation to the 4-index integral above can be written as

<math>

 (\tilde{pq}|\tilde{rs}) = (pq|rs) - (\delta_{pq}|rs) - (pq|\delta_{rs}) + (\delta_{pq}|\delta_{rs})

</math>