CamCASP/Numerical
CamCASP => Numerical Issues
Introduction
This page contains information related to the numerical accuracy of CamCASP.
Integral Switch
Integrals can be calculated using density-fitting (the default). But for a few kinds of 2-index integrals (nuclear, overlap, etc.) there is the possibility of calculating them without density-fitting. This can often be advantageous, in fact, for nuclear and overlap integrals, this is probably the thing to do whenever you can.
The energy modules all have the optional command
INTEGRAL Switch = <switch>
that can be used to set the method used to calculate the integrals. In general, Switch = 0 means use density-fitting, and Switch = 1 means use the exact evaluation (no density-fitting) if possible. Not all integrals can be evaluated without density-fitting. See df_integrals.F90 for details.
The 4-index Coulomb integrals are robust (see Robust Integrals for details.). So these can be obtained quite accurately using density-fitting. In any case, there is no other way of calculating these integrals, so the Switch command has no effect on these.
On the other hand, the nuclear and overlap integrals are not robust when density-fitting is used (the error made in these integrals is linear in the error made in the density. So these should be evaluated using Switch = 1. This is not the default in version 5.4.00 of the code, so it needs to be put in manually.
Here are some examples:
Auxiliary Basis Sets
MC or DC?
What sort of basis set