# '''User's Guide''': It's not up-to-date, nor does it contain helpful information about more complex calculations! |
# '''User's Guide''': It's not up-to-date, nor does it contain helpful information about more complex calculations! |
||
# The basis set parameters in parameter.f90 and gamint.F are not linked, but they should be. |
# The basis set parameters in parameter.f90 and gamint.F are not linked, but they should be. |
||
+ | # Get Energy-Scan to read the grid directly from the energy.dat or overlap.dat files. It can read these files, but doesn't use the grid information for ''another'' scan. |
||
+ | # Make Overlap-Module flexible enough to skip dimer configurations for which the energy fields are zero or '----'. |
||
# Van der Waals radii. Here's a comment from Anthony: |
# Van der Waals radii. Here's a comment from Anthony: |
||
<pre> |
<pre> |
Revision as of 18:56, 24 November 2008
CamCASP => To-Do list
CamCASP -- To Do
- Set up patch system for handling updates.
- Make tests automatic using James' test code.
- Take examples of energy scans etc. I have on my iLiad and put them here on the Wiki (and, eventually, in the User's Guide.
- Calculate perturbation matrix - currently in polarizability.f90 - in integrals.f90. At present it still uses Cartesian GTOs.
- Reduce the time the code spends in disk I/O.
- Reduce memory usage in the code (esp. DF objects).
- User's Guide: It's not up-to-date, nor does it contain helpful information about more complex calculations!
- The basis set parameters in parameter.f90 and gamint.F are not linked, but they should be.
- Get Energy-Scan to read the grid directly from the energy.dat or overlap.dat files. It can read these files, but doesn't use the grid information for another scan.
- Make Overlap-Module flexible enough to skip dimer configurations for which the energy fields are zero or '----'.
- Van der Waals radii. Here's a comment from Anthony:
There is another issue that needs thinking about. The van der Waals radii are hard-wired into camcasp, but they're not always appropriate -- particularly for hydrogen-bonded H, where a value of zero is more appropriate. At present a random grid doesn't sample the hydrogen-bonded region properly. Orient deals with this by associating the radius with an atom type, and assigning a type to each atom. Camcasp could do something similar, taking the type from the atomic number by default but allowing a different type to be specified. Or maybe you can think of another way of handling it.