==Cartesian versus Spherical auxiliary basis sets== |
==Cartesian versus Spherical auxiliary basis sets== |
||
What are the errors introduced when we use spherical GTOs in the auxiliary basis? |
What are the errors introduced when we use spherical GTOs in the auxiliary basis? |
||
+ | |||
+ | ===Water dimer=== |
||
+ | Sadlej/MC PBE0/AC |
||
+ | |||
+ | Units: kJ/mol |
||
+ | |||
+ | <pre> |
||
+ | Energies reference JK-tzvpp |
||
+ | Spherical Cartesian |
||
+ | ------------------------------------------ |
||
+ | E1elst -3.527 -3.736 |
||
+ | E1exch 0.129 0.137 |
||
+ | E2ind -37.08 --- |
||
+ | E2exind 0.101 --- |
||
+ | E2disp -1.263 --- |
||
+ | E2exdisp 0.003 --- |
||
+ | ========================================== |
||
+ | |||
+ | </pre> |
||
==Are the JK-tzvpp Aux bases any good?== |
==Are the JK-tzvpp Aux bases any good?== |
Revision as of 15:07, 3 March 2009
CamCASP => Programming => Status
ENERGY-SCAN
What's working:
- REDO_DF_ON_ROTATION = .TRUE.
- E1elst, E1exch, E2ind(UC),E2exind(UC),E2exdisp(UC),E2disp(UC)
- REDO_DF_ON_ROTATION = .FALSE.
- ???
What's not working and why:
- REDO_DF_ON_ROTATION = .TRUE.
- E2ind & E2disp: The DF-FDDS is created correctly for the first dimer configuration, but as it is not updated, it is incorrect for all subsequent configurations.
- E2exind & E2exdisp: Since these are obtained by scaling E2exind(UC) & E2exdisp(UC) using E2ind & E2disp (and their UC counterparts), these are wrong too.
Cartesian versus Spherical auxiliary basis sets
What are the errors introduced when we use spherical GTOs in the auxiliary basis?
Water dimer
Sadlej/MC PBE0/AC
Units: kJ/mol
Energies reference JK-tzvpp Spherical Cartesian ------------------------------------------ E1elst -3.527 -3.736 E1exch 0.129 0.137 E2ind -37.08 --- E2exind 0.101 --- E2disp -1.263 --- E2exdisp 0.003 --- ==========================================
Are the JK-tzvpp Aux bases any good?
- <math>\pi</math>-systems?
- H-bonded systems?
CamCASP and truncated MO space
When molecules are too long and/or basis sets are too diffuse, DALTON will often need to truncate the MO space to enable the SCF cycle to converge. So the effective number of MOs will be less than the size of the basis used. Since CamCASP assumes these two are equal (though it doesn't need to), this results in errors.
Where do changes need to be made to fix this?
- Reading in MOs.
- Constructing the density-matrix.
- Rotating MOs.
- DF
- Transformation code.