Line 9: Line 9:
 
# Reduce the time the code spends in [[ CamCASP/ToDo/diskIO | disk I/O]].
 
# Reduce the time the code spends in [[ CamCASP/ToDo/diskIO | disk I/O]].
 
# Reduce [[ CamCASP/ToDo/Memory | memory usage]] in the code (esp. DF objects).
 
# Reduce [[ CamCASP/ToDo/Memory | memory usage]] in the code (esp. DF objects).
  +
# '''User's Guide''': It's not up-to-date, nor does it contain helpful information about more complex calculations!
  +
# Van der Waals radii. Here's a comment from Anthony:
  +
<pre>
  +
There is another issue that needs thinking about. The van der Waals radii are hard-wired into camcasp,
  +
but they're not always appropriate -- particularly for hydrogen-bonded H, where a value of zero is more
  +
appropriate. At present a random grid doesn't sample the hydrogen-bonded region properly. Orient deals
  +
with this by associating the radius with an atom type, and assigning a type to each atom. Camcasp could
  +
do something similar, taking the type from the atomic number by default but allowing a different type to
  +
be specified. Or maybe you can think of another way of handling it.
  +
</pre>

Revision as of 11:24, 13 November 2008

CamCASP => To-Do list

CamCASP -- To Do

  1. Set up patch system for handling updates.
  2. Make tests automatic using James' test code.
  3. Take examples of energy scans etc. I have on my iLiad and put them here on the Wiki (and, eventually, in the User's Guide.
  4. Calculate perturbation matrix - currently in polarizability.f90 - in integrals.f90. At present it still uses Cartesian GTOs.
  5. Reduce the time the code spends in disk I/O.
  6. Reduce memory usage in the code (esp. DF objects).
  7. User's Guide: It's not up-to-date, nor does it contain helpful information about more complex calculations!
  8. Van der Waals radii. Here's a comment from Anthony:
There is another issue that needs thinking about. The van der Waals radii are hard-wired into camcasp,
but they're not always appropriate -- particularly for hydrogen-bonded H, where a value of zero is more
appropriate. At present a random grid doesn't sample the hydrogen-bonded region properly. Orient deals
with this by associating the radius with an atom type, and assigning a type to each atom. Camcasp could
do something similar, taking the type from the atomic number by default but allowing a different type to
be specified. Or maybe you can think of another way of handling it.